PRODUCTS

Micro pore filter paper,Micropore filter film,Micro porous filter membrane,Filter paper PTFE/PVDF/PET,Filter paper PTFE/PVDF/PP





Kind company specialized in manufacturing Micropore Filter paper,Micropore filter film,Micro porous filter membrane ,Micro void filter paper ,Filter paper PTFE/PVDF/PET,Filter paper PTFE/PVDF/PP etc.
The pore size:0.05μm--5μm  or according customer’s request.
Thickness:0.1mm-2.0mm. or according customer’s request.
Material: PTFE/PVDF/PET ,PTFE/PVDF/PP etc.
Protective layer:PET or PP.
Species: Filter paper which used in medical treatment
Filter paper which used in MBR(membrane Bio-Reactor),
Filter paper which used in insustry for air liquid oil filtration etc.
Battery membrane which used in battery.
Function: Acid resistance, alkali resistance, high temperature resistance, low temperature resistance
Applicable object: remove the dust particles ,bacteria in air, gas, oil, medicine, chemicals.
The seven types of membrance as follow:

 1.The Special Medical Absorption Membrane-Removal of White Cells in The Blood.

 


Type:function fiber.
Material:PBT,PP
Pore size:15,17,19,21,45,80μm
Thickness:0.2-1.5mm
Width:255mm,510mm.
Use:absorbtion, sieve filter.
The white blood cells can be absorbted by this membrane,the red blood cell and the blood platelets will remain.
Filtration mode:vertical current.
Performance: Acid resistance, alkali resistance, high temperature resistance, low temperature resistance,electrostatic prevention.
Applicable object:removal the white cells in the blood or their
 preparation.
High efficiency of removing white cell,High recovery efficiency of blood platelet and red blood cells,high blood compatibility
of biological,low filtration resistance.


Model number
  EB EC
Pore size(μm) 15-80
Efficiency of removing white cell(%) 99.99 99.99
recovery efficiency of red blood cells and blood platelet (%) 90/65 90/85
Hydrophilism 1cm membrane self absorption water height  ≥100mm/10 min
Be able to bear steam sterilization 125℃*30min,8 times(PBT)

2.The Special Medical Membrane-PTFE Gas Filter Membrane used in vein transfusion equipment.

 Type:microporous filter membrane.
Material:PTFE/PVDF(PET or PP)
Pore size:0.22,0.45,1.0,3.0μm
Width:255,510mm.
Thickness:0.1-0.2mm.
Filtration mode:vertical current.
Working temperature: ≤120℃
Use:sieve filter,gas solid separate,gas liquid separate.For example: remove the bacteria in air,gas water separate,remove the bacteria in liquid medicine.
Performance: Acid resistance, alkali resistance, high temperature resistance, low temperature resistance.
Applicable object:transfusing protection,gas filtration,instrument protection,the patient protection,organic reagent preparation,ventilate.
Scope of application:high filter accuracy and efficiency,big gas flux,strong hydrophobicity.
Operating pressure:--0.6 Mpa.

Model number X300 X100 X140 X120
Pore size(μm) 3.0 1.0 0.45 0.22
The first bubbling point(Mpa) 0.018 0.03 0.07 0.12
Membrane thickness(mm) 0.1-0.2
Supporting material PP(3),PET(4)
Airflow volume(m3/m2-min) 20 15 12 9.0
Note:Media of bubbling point test:absolute ethyl alcohol.


3.Membrane-Improved PVDF liquid Filter Membrane used in vein transfusion equipment.


 Type:microporous filter membrane.
Material:Improved PVDF.
Pore size:1.2,2.0,3.0,5.0μm
Width:255,510mm.
Thickness:0.1-0.2mm.
Use: sieve filter,liquid solid separate,for example liquid medicine filtration,reagent preparation.
Working temperature: ≤80℃
Operating pressure:--0.6 Mpa.
Performance: Acid resistance, alkali resistance, high temperature resistance, low temperature resistance.
Applicable object: transfusing treatment,liquid reagent preparation,organic reagent preparation.
Scope of application:high filter accuracy and efficiency,high throughput of liquid,good hydrophilia,non volatile,low loss of medicine.

Model number X120 X200 X300 X500
Pore size(μm) 1.2 2.0 3.0 5.0
The first bubbling point(KPa) 30 22 16 10
Membrane thickness(mm) 0.1-0.2
Supporting material PP(3),PET(4)
Pure Water flow volume(L/m2-min@10KPa 120 160 220 300
Note:
1.Media of bubbling point test:absolute ethyl alcohol.
2.The “X” in type column represent supporting material
.


4The Special Medical Filter Membrane-Double layer  PTFE gas filter membrane



 Type:microporous filter membrane.
Material:PTFE/PVDF(PP,PET)
Pore size:0.05,0.10,0.22,0.45μm
Width:255,510mm.
Thickness:0.15,0.20,0.30,0.5mm.
Use: sieve filter,gas solid separate,gas liquid separate.For example remove the bacteria in air,gas water separate, remove the granule in liquid medicine,
Filtration mode:vertical current.
Working temperature: ≤100℃.
Operating pressure: --0.6 Mpa.
Performance: Acid resistance, alkali resistance, high temperature resistance, low temperature resistance.
Applicable object:instrument protection,gas filter,patient protection, transfusing protection,organic reagent preparation.
Scope of application:used in transfusing apparatus or sensor.
Very high filter accuracy and efficiency, high throughput of gas,strong hydrophobicity.

Model number X240 X220 X210 X205
Pore size(μm) 0.45 0.22 0.10 0.05
The first bubbling point(MPa) 0.07 0.12 0.16 0.20
Membrane thickness(mm) 0.15,0.20,0.30,0.50
Supporting material PP(3),PET(4)
Air flow volume(m3/m2-min) 10 7.0 5.0 3.5
Note:
1.Media of bubbling point test:absolute ethyl alcohol.
Air flow volume test at △P=0.01MPa
2.The “X” in type column represent supporting material.


5.The Special Medical absorption Membrane-PVDF absorption membrane.

 Type:microporous filter membrane.
Material:PVDF(PET,PP)
Pore size:0.22,0.45,1.0,5.0μm
Width:255,510mm.
Thickness:0.07-1.0 mm.
Use:absorption separation,affinity absorption and separation,ion exchange separation
Filtration mode:vertical current or cross current.
Working temperature: ≤80℃.
Operating pressure: --0.6 Mpa.
Performance: Acid resistance, alkali resistance, high temperature resistance, low temperature resistance.,static-free.
Applicable object:refinement of water, liquid medicine,extracted liquid,organic reagant,concentrating body fluid for analysis.
Scope of application:for example, concentrating or refinement for super low concentration medicine(biology or plant or complex medicine).

Model number X500 X100 X040 X020
Pore size(μm) 5 1.0 0.45 0.22
The first bubbling point(MPa) 0.008 0.030 0.060 0.120
Membrane thickness(mm) 0.07-1mm
Supporting material Non(1),PP(3),PET(4)
Note:Media of bubbling point test:absolute ethyl alcohol.

6. The Special Medical Filter Membrane--Double layer PTFE/PVDF microporous filter membrane.

 Type:microporous filter membrane.
Material:PTFE/PVDF(PET,PP)
Pore size:0.02,0.05,0.10,0.22μm
Width:255,510mm.
Thickness:0.3,0.5,1.0mm.
Use: sieve filter,gas solid separate,gas liquid separate.For example: removing the bacteria in air,removing the impurity in oil,gas water separate,removing the feculence in liquid medicine.
Filtration mode:vertical current.
Working temperature: ≤100℃.
Operating pressure: --0.6 Mpa.
Performance: Acid resistance, alkali resistance, high temperature resistance, low temperature resistance.,hydrophobicity.
Applicable object:100% removing dust,granule,bacteria which in air,industrial gases,oil,liquid medicine,chemical.
Scope of application:health care,pharmaceuticals,water treatment,petrochemical engineering,food and beverage,iron and steel industry,electron ect.

Model number X220 X210 X205 X206
Pore size(μm) 0.22 0.10 0.05 ---
The first bubbling point(MPa) 0.12 0.16 0.20 0.30
Membrane thickness(mm) 0.3,0.5,1.0mm
Supporting material PP(3),PET(4)
Air flow volume(m3/m2-hr) 400 250 150 100
Note:
1.Media of bubbling point test:absolute ethyl alcohol.
Air flow volume test at P(enter)=0.1 Mpa,press diffenrential △P=0.01MPa
2.The “X” in type column represent supporting material


7. The Special Medical Filter Membrane—hydrophobicity and oleophobic microporous filter membrane.

 Type:microporous filter membrane.
Material:PVDF,N6,PET,PP
Pore size:0.45,1.0,5.0,10μm
Width:255,510mm.
Thickness:0.07-2.0 mm.
Use: sieve filter,gas solid separate,gas liquid separate.
Filtration mode:vertical current.
Working temperature: ≤150℃.
Operating pressure: --0.6 Mpa.
Performance: Acid resistance, alkali resistance, high temperature resistance, low temperature resistance.,hydrophobicity.
Applicable object:ventilate for blood bag,urine bag, transfusing protection.
Scope of application: high filter accuracy and efficiency

Model number QFF QFN QFP QFT
Material PVDF N6 PP PET
Pore size(μm) 0.45, 1.0, 5.0, 10
Membrane thickness(mm) 0.07-2 mm
Supporting material PP,PET